557+571 of Xebex International, Ltd.

Friction Tester
Model No.557 Series
557-Slip-angle.jpgModel AN557-Slip-friction.jpgModel TR-2



Used to measure coefficient of static friction of plastic film and paper etc.

Model AN (Inclined plane method)
A sample is placed on the inclined plane, the inclination angle is gradually increased, and then the angle at which the sled starts moving is determined.

- Testing standard: ASTM D4521 and JIS P8147
- Table inclination speed: 1.0, 1.5, 2.0, 2.7 & 3.0 (゚/sec.)
- Table max. angle: 70゚
- Table size: 320 x 210 mm
- Sled: 60 x 100mm, 1000g
- Indications: Coefficient of static friction, table angle (min. 0.1゚), table measuring start position lamp, sled measuring start position lamp, table out-of range stop alarm lamp
- Power source: 100V AC, single-phase, 1A, 50/60Hz (supplied with a transformer for local voltage)
- Dimensions & weight: 36(W) x 55(D) x 25(H) cm, Net approx. 28kg

LinkIconCatalogue


Model TR-2 (Horizontal plane method)
The coefficient of static friction and coefficient of dynamic friction are digitally displayed for direct reading.

- Application: Measuring friction coefficient (iS and iD) of plastic film and paper, etc.
- Testing standard: ISO-8295, ASTM D1894 and JIS K7125 & P8147
- Table speed: 5 to 1,500 mm/min.
- Table stroke: 1 to 200 mm
- Table size: 240 x 350 mm
- Load cell: Select from 10N (1kgf) or 20N (2kfg) <50N in option>
- Load range: x1, x2, x5, x10 and x20 (5 ranges)
- Sled: 63 x 63mm/200g (for plastic film or sheet), or 60 x 100mm/1000g (for paper or paperboard)
- Setting items: Table speed, table friction distance, load cell capacity, load range, weight, load unit N
- Power source: 100V AC, single-phase, 3A, 50/60Hz (supplied with a transformer for local voltage)
- Dimensions & weight: 70(W) x 35(D) x 32(H) cm, Net approx. 34kg

LinkIconCatalogue

 
Gas Transmission Rate Tester
Model No.571 Series
571-Gastransm.jpg

Used to measure gas transmission rate (gas barrier property) of packaging materials such as
plastic films



<Common Specifications>
- Testing standard: ASTM D1434 (Method M), ISO 2556, JIS K7126 (Method A)
- Dimensions of sample: 90 x 90 mm (transmission area: 38.5cm2) or 50 x 50 mm
- GTR measuring range: (A) 0.1 to 100 fm/Pa.s or (B) 1 to 1000 fm/Pa.s
* Type (A) or (B) to be selected on order.
- Type of gas: Oxygen, nitrogen, carbon dioxide, air, etc. (hydrogen, etc. available in option)
- Gas pressure: 0 to 200 kPa
- Measuring items: Gas transmission rate, gas transmission coefficient
- Data processing & control: PC with Windows-based software (included)
- Power supply: 100V AC, single phase, 50/60Hz (supplied with a transformer for local voltage)
- Air source: Pressure at 0.4 to 0.5 Mpa (Needed to measure diffusion coefficient: option)

Model BR-1
- Specimen to be tested at a time: 1
- Measuring temperature range: Room temperature
- Dimensions & weight: 38(W) x 40(D) x 47(H) cm, Net about 35kg

Model BR-3
- Specimen to be tested at a time: 3
- Measuring temperature range: Room temperature
- Dimensions & weight: 84(W) x 40(D) x 47(H) cm, Net about 70kg

Model BT-1
- Specimen to be tested at a time: 1
- Measuring temperature range: 5 to 90゚C (hot water circulation)
- Dimensions & weight: 38(W) x 40(D) x 47(H) cm, Net about 35kg

Model BT-3
- Specimen to be tested at a time: 3
- Measuring temperature range: 5 to 90゚C (hot water circulation)
- Dimensions & weight: 84(W) x 40(D) x 47(H) cm, Net about 70kg

LinkIconCatalogue