Density of Xebex International, Ltd.

Density/Specific Gravity Meter
Model DA-600 Series
DA-600.jpg

Bench type; 3 different models are available.



Compliance to ASTM D4052 & D5002 (Standard test method for density and relative density of Liquids or Crude Oil by digital density meter), as well as D1250, D1475, D4806, D5798, D5931 & ISO 12185 & 15212
- with 5.7'' colour TFT LCD display (640 x 480 dots), showing density, specific gravity, oscillation frequency, temperature, concentration & other messages
- Measuring range: 0 to 3 g/cm3
- Measuring temperature range: 0 to 90゚C (32 to 194゚F)
- Sampling by built-in auto peristaltic pump or manual syringe
- Minimum sample required: Approx. 2mL (by pump) or 1mL (by syringe)
- Measuring time: 2 to 10 minutes (auto) or 1 to 4 minutes (manual)
- With viscosity correction & density auto correction
- Method: Saving up to 100 different methods in the built-in memory
- Interfaces: LAN, USB (2 channels) & RS-232C (2 channels)
- Power source: 100 to 240V AC, 50/60Hz (supplied with AC adapter)
- Dimensions & weight: 320(W) x 365(D) x 250(H) mm, Net 18kg

Model DA-640
- Accuracy: +/-0.0001g/cm3
- Reproducibility: SD +/-0.00005g/cm3
- Temperature accuracy: +/-0.05゚C

Model DA-645
- Accuracy: +/-0.00005g/cm3
- Reproducibility: SD +/-0.00001g/cm3
- Temperature accuracy: +/-0.03゚C

Model DA-650
- Accuracy: +/-0.00002g/cm3
- Reproducibility: SD +/-0.000005g/cm3
- Temperature accuracy: +/-0.02゚C

CHD-502.jpgCHD-502* Some of Accessories in Option:
- IDP-100 Impact dot printer
- Soft CapE Software "Data Capture" for data transfer
- DCU-551N Auto cleaning & sampling unit
- CHD-502N Sample changer (room temp., 20mL x 30 vials)
- CHD-502C Sample changer (cooling type by water bath)
- CHD-502H Sample changer (R.T. to 80゚C), with peristaltic pump

LinkIconCatalogue

 
Density/Specific Gravity Meter
Model DA-100
DA-100.jpg

Compact and economy type



Measuring Range: 0 to 3g/cm3 (Accuracy : ±0.001g/cm3)
Temperature: 15゚C to 40゚C (±0.5゚C)
Temperature control: ±0.1゚C

- Measuring time: 20 to 90 sec.
- Min. sample required: approx. 1mL (by manual sampling by syringe)
- Display: 16 characters x 2 lines, with backlight
- with RS-232C; auto sampling unit & printer in option
- Power supply: 100 to 240V AC, 50/60Hz
- Dimensions & weight: 27.5(W) x 35(D) x 16.5(H) cm, Net about 6kg

* Some of Accessories in Option:
- ASU-100 Auto sampling unit
- IDP-100-12 Impact dot printer
- Soft CapE Software "Data Capture" for data transfer (USB type)

LinkIconCatalogue

 
Density/Specific Gravity Meter
Model DA-130N
DA-130N.jpg

Portable type



Measuring range: 0.0000 to 2.0000 g/cm3
Measuring accuracy: ±0.001 g/cm3 (Resolution at 0.0001g/cm3)
Temperature range: 0 to 40.0゚C (±0.5゚C)
Brix 0 to 84% at 0.01, Alcohol 0 to 100% at 0.1, avaialbe with %Conc

- Measuring method: Resonant frequency method
- Data storage: 1,100 samples
- External output: IrDA for PC
- Viscosity: Max. approx. 2,000 mPa-s
- Power source: 2 x 1.5V Alkaline AAA dry cells
- Battery life: Approx. 90 hours
- Dimensions & weight: 6.5(W) x 11.5(D) x 33.3(H) cm, Net about 360g

* Some of Accessories in Option:
- Set for high viscose samples
- IDP-100-22 Impact dot printer
- 98-029-0007 Infrared RS converter
- 98-404-0007 Conversion connector (Polar converter)

LinkIconCatalogue