Thermal Shock Chamber
TSA Series
- High temp. range: +60゚C to 250゚C
- Low temp. range: -70(-65)゚C to 0゚C
- Inner chamber: Please see below.
(A) High Performance Model
TSA-71H-W
- Inner chamber: 41(W) x 46(H) x 37(D) cm
- High temp. exposure range: +60゚C to +200゚C
- Low temp. exposure range: -70゚C to 0゚C
- Tem. fluctuation: +/-0.5゚C
- Tem. heat-up time: Within 15 minutes from ambient temp. to +200゚C
- Temp. pull down time: Within. 50 min. from ambient temp. to -75゚C
- Recovery conditions: 2 zone (temp. recovery time: within 5 min.)/High-temp. exposure: +150゚C (15 min).; Low-temp. exposure: -65゚C (15 min.)
- Test area load capacity: 30kg (when equally distributed)
- Power supply: 220V AC, three-phase, 60Hz or 380V AC, three-phase, 50Hz
- Dimensions & weight: 131(W) x 190(H) x 167(D) cm, Net 1,250kg
(B) Standard Performance Models
Model TSA-71S-A/W
- Inner chamber: 41(W) x 46(H) x 37(D) cm
- Temp. pull down time: Within. 40 min. from ambient temp. to -75゚C
- Recovery conditions: 3 zone (temp. recovery time: within 5 min.)/High-temp. exposure: +150゚C (30 min.).; Ambient temp. (5 min.); Low-temp. exposure: -65゚C (30 min.)
- Dimensions & weight: 131(W) x 190(H) x 137(D) cm, Net 1,050kg
- The other specifications are the same as those above.
Model TSA-101S-W
- Inner chamber: 65(W) x 46(H) x 37(D) cm
- Temp. pull down time: Within. 50 min. from ambient temp. to -75゚C
- Test area load capacity: 50kg (when equally distributed)
- Dimensions & weight: 155(W) x 190(H) x 137(D) cm, Net 1,150kg
- The other specifications are the same as those above.
Model TSA-201S-W
- Inner chamber: 65(W) x 46(H) x 67(D) cm
- Temp. pull down time: Within. 4 min. from ambient temp. to -75゚C
- Recovery conditions: 3 zone (temp. recovery time: within 10 min.)/High-temp. exposure: +150゚C (30 min.).; Ambient temp. (10 min.); Low-temp. exposure: -65゚C (30 min.)
- Dimensions & weight: 155(W) x 190(H) x 167(D) cm, Net 1,400kg
- The other specifications are the same as those above.
(C) Light Performance Models
Model TSA-41L-A
- Inner chamber: 24(W) x 46(H) x 37(D) cm
- High temp. exposure range: +60゚C to +200゚C
- Low temp. exposure range: -65゚C to 0゚C
- Tem. fluctuation: +/-0.5゚C
- Tem. heat-up time: Within 10 minutes from ambient temp. to +200゚C
- Temp. pull down time: Within. 75 min. from ambient temp. to -75゚C
- Recovery conditions: 3 zone (temp. recovery time: within 5 min.)/High-temp. exposure: +150゚C (30 min).; Ambient temp.: (5 min.); Low-temp. exposure: -55゚C (30 min.)
- Test area load capacity: 30kg (when equally distributed)
- Power supply: 220V AC, three-phase, 60Hz or 380V AC, three-phase, 50Hz
- Dimensions & weight: 114(W) x 190(H) x 117(D) cm, Net 730kg
Model TSA-71L-A
- Inner chamber: 41(W) x 46(H) x 37(D) cm
- Tem. heat-up time: Within 15 minutes from ambient temp. to +200゚C
- Temp. pull down time: Within. 45 min. from ambient temp. to -75゚C
- Dimensions & weight: 131(W) x 190(H) x 137(D) cm, Net 900kg
- The other specifications are the same as those above.
Model TSA-101L-A
- Inner chamber: 65(W) x 46(H) x 37(D) cm
- Temp. pull down time: Within. 70 min. from ambient temp. to -75゚C
- Test area load capacity: 50kg (when equally distributed)
- Dimensions & weight: 155(W) x 190(H) x 137(D) cm, Net 940kg
- The other specifications are the same as those above.
Model TSA-301L-A
- Inner chamber: 97(W) x 46(H) x 67(D) cm
- Temp. pull down time: Within. 45 min. from ambient temp. to -75゚C
- Recovery conditions: 3 zone (temp. recovery time: within 10 min.)
High-temp. exposure: +150゚C (30 min).; Ambient temp.: (5 min.); Low-temp. exposure: -55゚C (30 min.)
- Dimensions & weight: 187(W) x 190(H) x 167(D) cm, Net 1,420kg
- The other specifications are the same as those above.
Catalogue
(D) TSD & TSE Models
TSD-100TSE-11
Model TSD-100
- Inner chamber: 71(W) x 34.5(H) x 41(D) cm
- High temp. exposure range: +60゚C to +200゚C
- Low temp. exposure range: -65゚C to 0゚C
- Conforming to testing stardards MIL-STD-883, JIS C0025 & JASO-D001
- Conformingn to CE marking
- Power supply: 220V AC, three-phase, 60Hz or 380V AC, three-phase, 50Hz
Model TSE-11
- Inner chamber: 32(W) x 14.8(H) x 23(D) cm
- The other specifications are the same as those above.
Catalogue